Inverters & Solar
MPPT or PWM? Choosing a Solar Charge Controller in Ghana
· 9 min read · Energy Links Ghana
MPPT is the better controller, but the reason it is better in Ghana is not the reason most pages give you. The headline efficiency figure everyone quotes is published for cold panels or extremely hot ones. A rooftop array in Accra spends most of its working day in the temperature band where the manufacturer's own conclusion says a PWM controller is a perfectly reasonable low-cost choice. The real Ghanaian arguments for MPPT are about array voltage, cable, hazy mornings and room to grow.
The short version. A PWM controller connects your array more or less directly to your battery, so the array is dragged down to battery voltage and you lose whatever power the panels could have made at their own best operating point. An MPPT controller separates the two, runs the array at its optimum point and converts the result down to what the battery needs. MPPT wins on almost every system larger than a token one. But it wins for specific reasons, and knowing which ones apply to your site is how you avoid paying for a feature you will not use or skimping on one you need.
What a charge controller is for
The controller sits between the solar array and the battery bank. It is the device that decides how much current flows into the battery, holds the correct charging voltage, stops the bank being overcharged and, in most units, stops it being discharged below a floor. Everything downstream, including your inverter, is working from whatever the controller managed to put in.
That makes it an unglamorous component with an outsized effect. A good bank fed by a badly chosen controller will undercharge, and undercharging is how lead-acid banks die early. Inverter battery maintenance covers what that does to the plates.
What PWM actually does
Victron Energy puts it about as plainly as it can be put. In its summary of the white paper on the question, it describes the PWM controller as "in essence a switch that connects a solar array to a battery", with the result that "the voltage of the array will be pulled down to near that of the battery."
That sentence contains the entire limitation. A 12V nominal panel does not produce its maximum power at 12V. It produces it somewhere in the high teens, and its open-circuit voltage is higher still. A PWM controller cannot operate the panel there, because the panel is effectively tied to the battery. If the battery is sitting at 12.6V, that is roughly where the panel runs, and the difference between that point and the panel's real maximum power point is simply not collected.
PWM controllers are cheap, simple, robust and have very few components to fail. For a small system — a couple of panels, a modest bank, a light load — they do the job.
What MPPT actually does
The same Victron article describes the MPPT controller as "more sophisticated" and more expensive: "it will adjust its input voltage to harvest the maximum power from the solar array and then transform this power to supply the varying voltage requirement, of the battery plus load. Thus, it essentially decouples the array and battery voltages."
Decoupling is the important word. Because the controller is a DC to DC converter rather than a switch, your array no longer has to match your battery. Victron's own example is a 12 volt battery on one side and a string of cells producing 36 volts on the other. In practice that means you can wire panels in series, run the array at a much higher voltage than the bank, and let the controller sort it out.
The efficiency claim, read honestly
Here is where most comparisons mislead, including by omission.
Victron quotes the performance advantage of MPPT as "substantial (10% to 40%) when the solar cell temperature is low (below 45°C), or very high (above 75°C), or when irradiance is very low." Its conclusion on PWM is that it "is a good low cost solution for small systems only, when solar cell temperature is moderate to high (between 45°C and 75°C)."
Now consider a panel on a roof in Accra. Modules are rated at a cell temperature of 25 degrees, not an ambient one. The US Department of Energy and NREL state in their report on PV system performance that module performance ratings are measured at standard test conditions of 1,000 W per square metre and 25°C cell temperature, and that "in practice, however, the intensity of sunlight is usually less than 1,000 W/m2, and the cell temperature is typically hotter than 25°C." A roof-mounted module in full Ghanaian sun sits far above ambient — commonly somewhere in the range of 50 to 70 degrees for a mid-afternoon array with reasonable airflow behind it.
That is squarely inside the 45 to 75 band where Victron says PWM is an acceptable low-cost choice. So the honest statement is this: the 10% to 40% harvest advantage is not the argument for MPPT on a hot Ghanaian rooftop at 2pm. Anyone quoting that range as your expected gain is quoting it out of context.
The same DOE report gives the mechanism that makes heat matter at all: "PV module output decreases with temperature according to a temperature coefficient, which is the percent reduction in power per degree Celsius above a reference temperature," with a worked example coefficient of 0.004 per degree Celsius. Check the coefficient on your own module's data sheet. That loss happens with either controller — it is a property of the panel, not of the controller — which is exactly why it cannot be used as an argument for one over the other.
So why do we still specify MPPT for most Ghanaian systems?
Four reasons that have nothing to do with the headline figure.
Cable and array voltage. Victron gives the formula directly: cable losses are the cable resistance multiplied by the square of the current. Its conclusion is that "for a given cable loss, cable cross sectional area can be reduced by a factor of four when doubling the array voltage." Put panels in series, run the array at a higher voltage, carry less current for the same power, and you need thinner, cheaper cable — or you suffer less loss in the cable you already have. On a compound where the array is on the roof and the batteries are in a store room thirty metres away, this is the dominant argument.
Low irradiance, which Ghana has plenty of. Victron's own list of conditions where MPPT is substantially better includes "when irradiance is very low." Overcast rainy-season mornings, late afternoon, and harmattan haze all qualify. Under low irradiance a panel's voltage sags, and a PWM controller tied to a 12V battery may not get the panel above the voltage needed to charge at all. An MPPT controller with a series string has voltage to spare. Harmattan dust and solar panel cleaning covers the other half of the harmattan problem.
Panel choice. Large modern modules are not made to suit 12V batteries. Trying to run a high-voltage module through a PWM controller into a 12V bank wastes a large fraction of what you paid for. MPPT lets you buy the panel that is actually available and economic.
Room to grow. Almost every system we survey gets bigger. An MPPT controller with series strings can usually absorb more panels. A PWM controller sized to a small parallel array frequently cannot.
Victron's own threshold is useful here, and it is lower than most people expect: it calls MPPT "a compelling reason" as soon as array power exceeds "a few hundred Watts" on a 12 V battery, or several hundred watts on a 24 V or 48 V battery.
Five questions that decide it
- How big is the array? Past a few hundred watts on a 12V bank, MPPT starts paying for itself.
- What is the array voltage against the battery voltage? A big gap means a PWM controller throws away the difference.
- How long is the run from array to battery? Long runs favour higher array voltage, which means MPPT.
- Do you lose mornings to cloud or haze? Low irradiance is where MPPT's advantage is real in Ghana.
- Will the system grow? MPPT with series strings leaves headroom; a small parallel PWM array usually does not.
Sizing the controller
Whichever type you choose, two limits have to be respected and both come from the data sheets.
Current. The controller's rated output current must cover the array's short-circuit current with margin for irradiance spikes. This is why the question "what size charge controller for a 400W panel" has no single answer — it depends on the panel's current, the battery voltage and the controller type.
Voltage. For MPPT, the array's open-circuit voltage at the coldest temperature the site sees must stay below the controller's maximum input voltage. Ghana is not cold, which gives useful margin, but harmattan nights and highland sites still move the number, and open-circuit voltage rises as temperature falls.
Get either wrong and the controller is either throttling your array or being damaged by it. This is the part we check on a site survey rather than over the phone.
Frequently asked questions
Is MPPT always better than PWM?
For harvest at a given array size, yes, and by more in some conditions than others. For value on a very small system, not necessarily. Victron's own conclusion keeps PWM as a good low-cost solution for small systems in the moderate-to-high cell temperature band, which is where a Ghanaian rooftop mostly sits.
How much more power will MPPT give me?
Nobody can tell you honestly without your array, your bank, your cable run and your site. The 10% to 40% range Victron publishes is specifically for cold cells, very hot cells or very low irradiance. Treat any flat percentage promise with suspicion.
Can I use a PWM controller with a 48V battery bank?
Only with an array whose nominal voltage matches the bank, which in practice means a large series-parallel arrangement of nominal-voltage panels. It is usually the wrong economics. Higher-voltage banks are where MPPT is most clearly indicated.
Does the controller type affect battery life?
Indirectly, and significantly. A controller that cannot complete a charge leaves sulphate hardening on lead-acid plates. In low light, an MPPT controller with a series string will often finish a charge that a PWM controller cannot start.
Do I need a charge controller if I have a hybrid inverter?
Most hybrid inverters have an MPPT controller built in. Check the data sheet for its maximum input voltage and current before adding panels. Hybrid or off-grid solar explains which architecture suits which site.
Will an MPPT controller fix a weak battery bank?
No. It will charge a good bank better. Which battery for my inverter and how long a 200Ah battery lasts deal with the bank itself.
Getting the specification right
The controller is a small part of a solar budget and a large part of whether the system performs. The choice depends on your array, your bank voltage, the distance between them and how much you plan to add later — which is why we survey before we specify.
Our engineers do the site survey, the installation and the after-sales servicing, from our base in Mamprobi, Accra. Get in touch or see what we stock. We quote after the survey, because a controller specified without seeing the roof is a guess.
Need help choosing the right equipment?
Our engineers will size it against your actual load, not a guess.
Talk to us